Wsparcie Czujników Przemysłowych
Wsparcie Ochrony przed wybuchem

Distance sensor VDM28-50-R1-IO/110/116/122-Ex

VDM28-50-R1-IO/110/116/122-Ex
  • Retroreflective laser distance sensor
  • Measuring method PRT (Pulse Ranging Technology)
  • Accurate, clear, and reproducible measuring results
  • Red laser as the light emitter
  • Version with laser class 1
  • Version with IO-Link interface
  • Version with analog output
  • Suitable for operation in Zone 1, Zone 2, Zone 21 and Zone 22

Please note: All product-related documents, such as certificates, declarations of conformity, etc., which were issued prior to the conversion under the name Pepperl+Fuchs GmbH or Pepperl+Fuchs AG, also apply to Pepperl+Fuchs SE.

Pobierz pełną kartę katalogową w formie pliku PDF:


Dane techniczne  VDM28-50-R1-IO/110/116/122-Ex

Opis produktu
Universal distance sensor, measurement to reflector, IO-Link interface, measuring method PRT, 50 m detection range, red laser light, laser class 1, push-pull output, analog output, terminal block
General specifications
Device typeGUBW1.D.OS-VDM28-50-R1
Measurement range0.5 ... 50 m
Reference targetOFR-100/100
Light sourcelaser diode
typ. service life 85,000 h at Ta = +25 °C
Light typemodulated visible red light
Laser nominal ratings
NoteLASER LIGHT , DO NOT STARE INTO BEAM
Laser class1
Wave length660 nm
Beam divergence< 1.5 mrad
Pulse lengthapprox. 4 ns
Repetition rate250 kHz
max. pulse energy< 1.5 nJ
Angle deviationmax. ± 2°
Measuring methodPulse Ranging Technology (PRT)
Diameter of the light spot< 50 mm at a distance of 50 m at 20 °C
Ambient light limit50000 Lux
Temperature influencetyp. ≤ 0.25 mm/K
Functional safety related parameters
MTTFd200 a
Mission Time (TM)10 a
Diagnostic Coverage (DC)0 %
Indicators/operating means
Operation indicatorLED green
Function indicator2 LEDs yellow for switching state
Teach-in indicatorTeach-In: LED green/yellow equiphase flashing; 2.5 Hz
Teach Error:LED green/yellow non equiphase flashing; 8.0 Hz
Control elements5-step rotary switch for operating modes selection (threshold setting and operating modes)
Control elementsSwitch for setting the threshold values
Electrical specifications
Operating voltage10 ... 30 V DC / when operating in IO-Link mode: 18 ... 30 V
Ripple10 % within the supply tolerance
No-load supply current≤ 70 mA / 24 V DC
Time delay before availability1.5 s
Interface
Interface typeIO-Link
ProtocolIO-Link V1.0
Cycle timemin. 2.3 ms
ModeCOM2 (38.4 kBit/s)
Process data width16 bit
SIO mode supportyes
Output
Signal outputPush-pull output, short-circuit protected, reverse polarity protected
Switching voltagemax. 30 V DC
Switching currentmax. 100 mA
Measurement output1 analog output 4 ... 20 mA, short-circuit/overload protected
Switching frequency50 Hz
Response time10 ms
Conformity
Electromagnetic compatibilityEN 61000-6-2, EN 61000-6-4
Laser safetyIEC 60825-1:2007
Measurement accuracy
Absolute accuracy± 25 mm
Repeat accuracy< 5 mm
Approvals and certificates
IECEx approvalIECEx INE 14.0042X
ATEX approvalINERIS 14 ATEX 0035X
MarkingEx-Hexagon II 2 GD
Ex db IIC T6 Gb
Ex tb IIIC T85°C Db
Protection classIII
Ambient conditions
Ambient temperature-30 ... 45 °C (-22 ... 113 °F)
Storage temperature-30 ... 70 °C (-22 ... 158 °F)
Mechanical specifications
Cable glandClamping range 3 ... 8.5 mm
Enclosure coverthreaded round cover
Cover fixingflamepath thread
Flamepath greasepetroleum jelly
Degree of protectionIP66
ConnectionConnection terminals, max. wire cross-section 2.5 mm2
Material
Enclosurealuminum alloy
Glassthermo-resistant tempered glass
Finishepoxy coated RAL 7005 (grey)
Massapprox. 6.6 kg
GroundingM6 external grounding points

Classifications

SystemClasscode
ECLASS 13.027270916
ECLASS 12.027270916
ECLASS 11.027270801
ECLASS 10.0.127270801
ECLASS 9.027270801
ECLASS 8.027270801
ECLASS 5.127270801
ETIM 9.0EC001825
ETIM 8.0EC001825
ETIM 7.0EC001825
ETIM 6.0EC001825
ETIM 5.0EC001825
UNSPSC 12.141111613

Details: VDM28-50-R1-IO/110/116/122-Ex

Function

The VDM28 distance measurement device employs Pulse Ranging Technology (PRT). It has a repeat accuracy of 5 mm with an operating range of 0.5 ... 50 m and an absolute accuracy of 25 mm.

Product Documentation: VDM28-50-R1-IO/110/116/122-Ex

Language Selection:
Product informationJęzykTyp plikuRozmiar pliku
Installation and user instructions for offline parameterization of IO-Link sensorsENGPDF1788 KB

Approvals: VDM28-50-R1-IO/110/116/122-Ex

Language Selection:
CertificatesNr. certyfikatuJęzykTyp plikuRozmiar pliku
Canada USA UL Ordinary LocationE87056ALLLINK---
Europe INERIS ATEXINERIS 14 ATEX 0035XALLPDF529 KB
Worldwide INERIS IECEx Certificate of ConformityIECEx INE 14.0042XALLLINK---
Declaration of Conformity
EU Declaration of Conformity (P+F) / EU-Konformitäterklärung (P+F)DOC-0845CALLPDF308 KB
UK Declaration of Conformity (P+F) / UK-Konformitäterklärung (P+F)DOC-5273ALLPDF297 KB

Produkty powiązane: VDM28-50-R1-IO/110/116/122-Ex

Accessories

EtherNet/IP IO-Link master with 8 inputs/outputsfa

PROFINET IO IO-Link master with 8 inputs/outputsfa
Universal DTM host platform, For all DTMs of Pepperl+Fuchs, Approved FDT/DTM technology, Free of charge, Internet download possiblepa
Reflector with Micro-structure, rectangular 82 mm x 60 mm, mounting holesfa
Reflector with Micro-structure, rectangular 50.9 mm x 50.9 mm, mounting holes, fixing strapfa
Reflector with Micro-structure, hexagonal 78 mm x 61 mm, mounting holesfa
Reflective tape 100 mm x 100 mmfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, push-in terminalsfa
PROFINET IO IO-Link master with 8 inputs/outputs, DIN rail, screw terminalfa
IO-Link master, supply via USB port or separate power supply, LED indicators, M12 plug for sensor connectionfa
Ethernet IO-Link module with 8 inputs/outputsfa
Ethernet IO-Link module with 8 inputs/outputsfa
EtherNet/IP IO-Link master with 8 inputs/outputs, DIN rail, push-in connectorsfa
Mounting aid for VDM28 seriesfa

Odkryj unikalne laserowe czujniki triangulacyjne SmartRunner zintegrowane z czujnikiem wizyjnym 2D wyposażonym w diody LED…

Model R2000 zapewnia niezawodne i niezwykle precyzyjne wyniki pomiarów — z widocznością 360° bez przerw...

Pomiar w 3D lub z dużą prędkością: Seria R2300 oferuje odpowiedni czujnik LiDAR dla każdego wyzwania. Dowiedz się więcej o zaletach, technologii i obszarach zastosowań…

Czujniki fotoelektryczne z serii R10x i R20x

Po raz pierwszy dostępna jest pełna gama rozwiązań obejmujących urządzenia fotoelektryczne oraz innowacyjne technologie w identycznych obudowach. Użytkownicy korzystają z jednolitej koncepcji obsługi w ramach całej oferty. Poznaj serie R100, R101, R103, R200 i R201...

Dzięki najnowocześniejszym technologiom czujniki odległości oferują najwyższy poziom precyzji i niezawodności…