国を選択してください
6000-TSEN-01 Temperature Sensor
Temperature sensor for use with 6000 series purge and pressurization system
主なメリットの概要
- Remote sensor
- Suitable for Zone 1 and Division 1 mounting
- Intrinsically safe when used with the 6000 Series purge system control unit
- Easy mounting for temperature measurements up to 3 m from the temperature hub






注記
Pepperl+Fuchs GmbH または Pepperl+Fuchs AG の名義で、会社形態の変更前に発行された証明書、適合宣言書などの製品関連文書はすべて、Pepperl+Fuchs SE に対しても有効です。
EN
- EN
- DE
6000-TSEN-01の技術データ
| Series | 6000 Series | |
| System | Type X Purge ; Ex pxb Purge |
| Connection | |||||
| |||||
| Rated voltage | Ur | 5.5 V DC | |||
| Rated current | Ir | max. 10 mA | |||
| Open loop voltage | 9.6 V | ||||
| Distance | 3 m from 6000 control unit 3 m from 6000-TEMP-01 | ||||
| Ambient temperature | -20 ... 100 °C (-4 ... 212 °F) | |
| Storage temperature | -40 ... 100 °C (-40 ... 212 °F) | |
| Relative humidity | < 95 % non-condensing | |
| Vibration resistance | 1 g , 10 ... 100 Hz , all axes | |
| Impact resistance | 30 g, 11 ms, all axes |
| Housing material | Ryton BR III BL | |||||||
| Degree of protection | IP65 | |||||||
| Cable | Gray PVC | |||||||
| ||||||||
| Mass | approx. 110 g | |||||||
| Dimensions | 50 mm x 25 mm x 5 mm | |||||||
| Mounting | panel or DIN rail mounting | |||||||
| EU-type examination certificate | UL/Demko 07 ATEX 0705753X |
| UL approval | File no: E184741 | ||||
| |||||
| IECEx approval | IECEx UL 08.0003X | ||||