LB8107* Com Unit
Com unit for Modbus RTU
主なメリットの概要
- Interface between the I/O modules and the PCS/PLC
- Com unit for 80 analog or 184 digital channels
- Communication via MODBUS RTU
- Mounting in Zone 2, Class I/Div.2 or in the safe area
- HART communication via service bus
- Configuration via FDT 1.2 DTM
- Non-volatile memory for configuration and parameter settings
- Self configuration in redundant systems
- Permanently self-monitoring
- Outputs drive to safe state in case of failures
- Module can be exchanged under voltage
もっと見る






注記
Pepperl+Fuchs GmbH または Pepperl+Fuchs AG の名義で、会社形態の変更前に発行された証明書、適合宣言書などの製品関連文書はすべて、Pepperl+Fuchs SE に対しても有効です。
EN
- EN
- DE
LB8107*の技術データ
| Connection | backplane bus | |
| Rated voltage | Ur | 5 V DC , only in connection with the power supplies LB9*** |
| Power consumption | 2 W |
| Fieldbus type | MODBUS RTU | |||||||
| MODBUS RTU | ||||||||
| ||||||||
| Number of stations per bus line | max. 245 (MODBUS), max. 119 (service bus) | |||||||
| Number of channels per station | max. 80 analog, max. 184 digital (standard configuration) | |||||||
| Number of stations per bus segment | max. 31 (RS-485 standard) | |||||||
| Number of repeaters between Master and Slave | max. 3 | |||||||
| Supported I/O modules | all LB remote I/O modules | |||||||
| Bus length | max. 1200 m (FOL, 38.4 kBd), max. 1200 m (copper cable, 38.4 kBd) | |||||||
| FOL (fiber optic link) | additional hardware required | |||||||
| Addressing | via configuration software | |||||||
| MODBUS address | standard compliant (factory standard setting: 126) | |||||||
| Service bus address | max. 119 , redundancy address = base + 128 (automatic) | |||||||
| HART communication | via service bus | |||||||
| Redundancy | system dependent | |||||||
| Connection | backplane bus | |
| Redundancy | via backplane |
| LED indication | LED 1 (power supply): On = operating, fast flash = cold start LED 2 (collective alarm): On = internal fault, flashing = no Modbus RTU connection LED 3 (status process bus): flashing = Modbus receive channel active LED 4 (status service bus): flashing = service bus receive channel active LED 5 (operating mode): flashing 1 (1:1 ratio) = active, normal operation; flashing 2 (7:1 ratio) = active, simulation LED 6 (status process bus): flashing = Modbus response channel active LED 7 (status servicebus): flashing = service bus response channel active |
| Electromagnetic compatibility | |||||
| |||||
| Electromagnetic compatibility | NE 21 | |
| Degree of protection | IEC 60529 | |
| Fieldbus standard | IEC 61158-2 | |
| Environmental test | EN 60068-2-14 | |
| Shock resistance | EN 60068-2-27 | |
| Vibration resistance | EN 60068-2-6 | |
| Damaging gas | EN 60068-2-42 | |
| Relative humidity | EN 60068-2-56 |
| Ambient temperature | -20 ... 60 °C (-4 ... 140 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 95 % non-condensing | |
| Shock resistance | shock type I, shock duration 11 ms, shock amplitude 15 g, number of shocks 18 | |
| Vibration resistance | frequency range 10 ... 150 Hz; transition frequency: 57.56 Hz, amplitude/acceleration ± 0.075 mm/1 g; 10 cycles frequency range 5 ... 100 Hz; transition frequency: 13.2 Hz amplitude/acceleration ± 1 mm/0.7 g; 90 minutes at each resonance | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection | IP20 (module) , mounted on backplane | |
| Connection | via backplane | |
| Mass | approx. 120 g | |
| Dimensions | 32.5 x 100 x 102 mm (1.28 x 3.9 x 4 inch) |
| Certificate | PF 08 CERT 1234 X | ||||
| |||||
| Directive conformity | |||||
| |||||
| ATEX approval | PF 08 CERT 1234 X | |||||||||||||
| UL approval | E106378 | |||||||||||||
| ||||||||||||||
| IECEx approval | BVS 09.0037X | |||||||||||||
| ||||||||||||||
| EAC approval | Russia: RU C-IT.MIII06.B.00129 | |||||||||||||
| Marine approval | ||||||||||||||
| ||||||||||||||
| System information | The module has to be mounted in appropriate backplanes (LB9***) in Zone 2 or outside hazardous areas. Here, observe the corresponding declaration of conformity. For use in hazardous areas (e. g. Zone 2, Zone 22 or Div. 2) the module must be installed in an appropriate enclosure. | |
| Supplementary information | EC-Type Examination Certificate, Statement of Conformity, Declaration of Conformity, Attestation of Conformity and instructions have to be observed where applicable. For information see www.pepperl-fuchs.com. |
関連ページ
さらに詳しい情報をお探しですか?関連ページでぜひご覧ください。