国を選択してください
S1SD-1AI-2C Transmitter Power Supply
Power supply or signal splitter
主なメリットの概要
- 1-channel signal conditioner
- 24 V DC supply
- Input 2-wire transmitters
- Dual output 0/4 mA ... 20 mA
- Signal splitter (1 input and 2 outputs)
- Accuracy 0.1 %
- Connection via screw terminals
もっと見る
希望するタイプ











注記
Pepperl+Fuchs GmbH または Pepperl+Fuchs AG の名義で、会社形態の変更前に発行された証明書、適合宣言書などの製品関連文書はすべて、Pepperl+Fuchs SE に対しても有効です。
EN
- EN
- DE
- ES
- FR
- PL
S1SD-1AI-2Cの技術データ
| Signal type | Analog input | |
| Operation time | MTBF: 313 a acc. to SN 29500 stationary continuous operating, average ambient temperature 40 °C (104 °F) |
| Connection | Power Bus or terminals 1-, 2+ | |
| Rated voltage | Ur | 16.8 ... 31.2 V DC |
| Power dissipation | 0.8 W | |
| Power consumption | 1.4 W |
| Connection side | field side | |
| Connection | terminals 5+, 6- | |
| Input signal | 0/4 ... 20 mA | |
| Open circuit voltage/short-circuit current | ≤ 22 V / 35 mA | |
| Input resistance | ≤ 25 Ω | |
| Transmission range | linearity range: -1 ... 110 % | |
| Available voltage | 16 V at 20 mA |
| Connection side | control side | |||||||
| Ripple | ≤ 10 mV eff | |||||||
| Output I | ||||||||
| ||||||||
| Output II | ||||||||
| ||||||||
| Accuracy | max. 0.1 % of full-scale value | |
| Influence of ambient temperature | < 100 ppm/K of full-scale value | |
| Frequency range | 0 ... 100 Hz | |
| Rise time/fall time | ≤ 3.5 ms |
| Output/power supply | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min | |
| Input/Other circuits | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min | |
| Output I/II | safe electrical isolation by reinforced insulation according to IEC/EN 61010-1, rated insulation voltage 300 Veff test voltage 3 kV, 50 Hz, 1 min |
| Labeling | space for labeling at the front |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | IEC 60529:2001 | |
| Protection against electrical shock | EN 61010-1:2010 |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Damaging gas | designed for operation in environmental conditions acc. to ISA-S71.04-1985, severity level G3 |
| Degree of protection | IP20 | ||||||||||
| Connection | screw terminals | ||||||||||
| Core cross section | 0.5 ... 2.5 mm2 (20 ... 14 AWG) | ||||||||||
| Mass | approx. 70 g | ||||||||||
| Dimensions | 6.2 x 97 x 107 mm (0.24 x 3.82 x 4.21 inch) (W x H x D) , housing type S1 | ||||||||||
| |||||||||||
| Mounting | on 35 mm DIN mounting rail acc. to EN 60715:2001 | ||||||||||
| Certificate | DEMKO 16 ATEX 1750X | ||||
| |||||
| Directive conformity | |||||
| |||||
| UL approval | E106378 | |||||||
| IECEx approval | ||||||||
| ||||||||
| Supplementary information | Observe the certificates, declarations of conformity, instruction manuals, and manuals where applicable. For information see www.pepperl-fuchs.com. |