글로벌 웹사이트로 이동
Switching function: Normally open (NO), Output type: NPN, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: NPN, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 36 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4404 / AISI 316L, Degree of protection: IP65, Threading: M12 x 1
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 36 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4404 / AISI 316L, Degree of protection: IP65, Threading: M12 x 1
Switching function: Normally open (NO), Output type: NPN, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 36 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4404 / AISI 316L, Degree of protection: IP65
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 36 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4404 / AISI 316L, Degree of protection: IP65
Switching function: Normally open (NO), Output type: NPN, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M18, Construction type: Cylindrical, thread, Series: Cylindrical type, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1
Switching function: Normally open (NO), Output type: NPN, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: NPN, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
magnetic field resistant, Switching function: complementary, Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 4-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
magnetic field resistant, Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: PBT, Degree of protection: IP67
Switching function: Normally open (NO), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: BVS 13 ATEX E 074 X, Equipment protection level Da: BVS 13 ATEX E 074 X, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: NAMUR, Installation: flush, Output type: 2-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: BVS 13 ATEX E 074 X, Equipment protection level Da: BVS 13 ATEX E 074 X, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 60 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 60 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1
Switching function: Normally open (NO), Output type: NPN, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 60 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: cable, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67
Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Thread mold: M30, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 10 ... 60 V DC, Potentiometer: sensitivity adjustment, Type of voltage: DC, Connection type: Connector plug, Housing material: Stainless steel 1.4305 / AISI 303, Degree of protection: IP67, Threading: M12 x 1
Switching function: Normally open (NO), Output type: PNP, Installation: non-flush, Output polarity: DC, Output type: 3-wire, Construction type: Rectangular, Series: Rectangular type, Operating voltage: 10 ... 30 V DC, Type of voltage: DC, Connection type: cable, Housing material: PVDF, Degree of protection: IP68
Switching function: Normally open (NO), Output type: NAMUR, Installation: non-flush, Output type: 2-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Type of voltage: DC, Equipment protection level Ga: IECEx TUN 20.0014X, Equipment protection level Gb: IECEx TUN 20.0014X, Equipment protection level Da: IECEx TUN 20.0014X, Equipment protection level Ga: TÜV 03 ATEX 2003 X, Equipment protection level Gb: TÜV 03 ATEX 2003 X
Print mark contrast sensor, 11 mm detection range, RGB light parallel with the longitudinal direction of the housing, light/dark ON, external Teach-In, 2 push-pull outputs, M12 plug, Diffuse mode sensor for recording any print mark, Teach-in, static and dynamic, 50 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and blue
Print mark contrast sensor, 9.5 mm detection range, RGB light, light/dark on, external Teach-in, push-pull output, M12 plug, Diffuse mode sensor for recording any print mark, Static teach-in: automatic switching threshold adaptation, Optical system exchangeable by 90°, 30 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and blue
Print mark contrast sensor, 9.5 mm detection range, RGB light with circular light spot, light/dark on, external Teach-in, push-pull output, M12 plug, Diffuse mode sensor for recording any print mark, Static teach-in: automatic switching threshold adaptation, Optical system exchangeable by 90°, 30 µs response time, suitable for extremely rapid scanning processes, 3 emitter colors: green, red and blue
Connection board for K-System HART Multiplexer, 16-channel, Interface for series connection or parallel connection, Integrated, switchable 220 Ω resistor, Connection via screw terminals
1-channel, Field mount module, ½ NPT thread, Stainless steel housing, Max. surge current (8/20 µs) 20 kA, 500 V isolation from earth, Suitable for hazardous area, Up to SIL 3 acc. to IEC/EN 61508
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, infrared light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Infrared light
Photoelectric slot sensor, zinc pressure diecast housing, 30 mm slot width, red light, light/dark on, sensitivity adjuster, DC version, PNP output, 3 pin M8 plug, Optimized for the detection of small parts, High switching frequency, Multiple device installation possible, no mutual interference (no cross-talk), Sensitivity adjuster and light-on/dark-on changeover switch as standard features of this series, Visible red light
Miniature photoelectric slot sensor for the detection of small parts, L design, fork width 5 mm, infrared light, NPN outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, L design, fork width 5 mm, infrared light, NPN outputs, flat connector, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, T design, fork width 5 mm, infrared light, NPN outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, T design, fork width 5 mm, infrared light, NPN outputs, flat connector, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, U design, fork width 5 mm, infrared light, NPN outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, U design, fork width 5 mm, infrared light, NPN outputs, flat connector, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, Y design, fork width 5 mm, infrared light, NPN outputs, fixed cable, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Miniature photoelectric slot sensor for the detection of small parts, Y design, fork width 5 mm, infrared light, NPN outputs, flat connector, Miniature design, Optimized for the detection of small parts, High switching frequency, Simple and fast mounting, Clearly visible LED functional display
Fieldbus power supply, module for fieldbus power hub, Output: 21 ... 23 V/500 mA, Voltage limitation for Entity ic and Ex nL, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: Zone 2 - high-power trunk, Instrument location / spur protection: Zone 2 - all relevant types of protection, Function: Fieldbus Power Supply
Fieldbus power supply, module for fieldbus power hub, Output: 28 ... 30 V/500 mA, High-power trunk for high device count and long cable lengths, With galvanic isolation, Installation in Zone 2/Class I, Div. 2, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada, Device coupler location: non-explosion hazardous area, Zone 2 - high-power trunk, Zone 1 - high-power trunk, Division 2 - high-power trunk, Division 1 - high-power trunk
Advanced diagnostic module, plug-in module for the fieldbus power hub, Comprehensive diagnostics for fieldbus physical layer and power supply, Plug-in Module for the FieldConnex Power Hub, Precise measurements through passive circuits, For commissioning, online monitoring and troubleshooting, For FOUNDATION Fieldbus H1 and PROFIBUS PA, IECEx approval, International, Europe, USA, Canada
1-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR input, Usable as signal splitter (1 input and 2 outputs), 2 relay contact outputs, Fault relay contact output, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 1-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact
2-channel isolated barrier, 24 V DC supply (bus powered), Dry contact or NAMUR inputs, 2 relay contact outputs, Line fault detection (LFD), Reversible mode of operation, Up to SIL 2 acc. to IEC/EN 61508, Housing width: 12.5 mm, Number of channels: 2-channel, Safety Integrity Level (SIL): SIL 2, Rated voltage: 19 ... 30 V DC bus powered via Termination Board, Field device: NAMUR sensor, Field device [2]: volt-free contact, Line fault detection, Type: 2 x relay (NO contact), Fault indication output
32-channel, 24 V DC supply, HART field device input (revision 5 to 7), RS-485 interface, Up to SIL 3 acc. to IEC/EN 61508
32-channel, 24 V DC supply, Interface for serial or parallel wiring options, Dual RS 485 connections, Slot for HART Multiplexer, Number of channels: 32 unbalanced signal loops
Output type: Analog current output or analog voltage output, Installation: quasi flush, Output polarity: DC, Output type: 4-wire, Thread mold: M12, Construction type: Cylindrical, thread, Series: Cylindrical type, Operating voltage: 15 ... 30 V , residual ripple 20 % UB, Type of voltage: DC, Output type: 0 ... 10 V / 4 ... 20 mA, Connection type: Connector plug, Housing material: chromium plated brass, Degree of protection: IP67, Threading: M12 x 1
50 / 13997