국가 선택
VBA-4E4A-G20-ZEJ/M48L-P12 ASi Motor Roller Module
G20 MDR module with AS-Interface for 4 digital inputs and 2 connections for MDRs (48 V)
주요 혜택 한눈에 보기
- Inputs for 3-wire sensors
- A/B node with extended addressing possibility for up to 62 nodes
- Connection of motors and sensors via M8 connectors
- Power supply of outputs from auxiliary voltage AUX
- Supply for inputs from AS-Interface
- Cable piercing method with gold plated contact pins
- Outputs for 48 V DC roller motors
더 보기









참고
Pepperl+Fuchs GmbH 또는 Pepperl+Fuchs AG 명의로 전환 이전에 발행된 인증서, 적합성 선언서 등 모든 제품 관련 서류는 Pepperl+Fuchs SE에도 적용됩니다.
EN
- EN
- DE
- FR
VBA-4E4A-G20-ZEJ/M48L-P12 기술 데이터
| Node type | A/B node | |||||||||||||
| AS-Interface specification | V3.0 | |||||||||||||
| Required gateway specification | ≥ V3.0 | |||||||||||||
| Profile | S-7.A.7 | |||||||||||||
| ||||||||||||||
| UL File Number | E223772 "For use in NFPA 79 Applications only" | |||||||||||||
| MTBF | 98 a | |||||||||||||
| Compatible roller motors | Interroll EC5000 48 V AI (20 W / 35 W / 50 W) MTA MRD50 (A interface, 48 V to 44 W) | |||||||||||||
| LED FAULT | error display; LED red red: communication error or address is 0 red flashing: overload of sensor supply or speed signal overload or external auxiliary voltage UAUX missing | |
| LED ERR | Motor fault: 2 LED yellow | |
| LED PWR | AS-Interface voltage; green LED green: voltage OK green flashing: address 0 or sensor supply overload or speed signal overload or external auxiliary voltage UAUX missing | |
| LED AUX | ext. auxiliary voltage UAUX; dual LED green/red green: voltage OK red: reverse voltage | |
| LED IN | switching state (input); 2 LED yellow | |
| LED FUSE | Motor power supply; 2 green LEDs | |
| LED DIR | Motor rotation direction; yellow LED | |
| LED MOT | Motor active; 2 yellow LEDs |
| Auxiliary voltage (output) | UAUX | 36 ... 56 V DC PELV |
| Rated operating voltage | Ue | 26.5 ... 31.6 V from AS-Interface |
| Rated operating current | Ie | ≤ 25 mA (without sensors) / max. 170 mA |
| Number/Type | 2 Inputs for 3-wire sensors (PNP), DC | |
| Supply | from AS-Interface | |
| Current loading capacity | 100 mA , overload and short-circuit protected | |
| Input current | ≤ 6 mA (internally limited) | |
| Switching point | according to DIN EN 61131-2 0 (undamped) ≤ 0.5 mA 1 (damped) ≥ 2.0 mA | |
| Signal delay | < 1 ms (input/AS-Interface) | |
| Input filter | 2 ms |
| Number/Type | 2 outputs for DC roller motors (MOT1, MOT2) | |
| Supply | from external auxiliary voltage UAUX | |
| Current | 3.5 A continuous current , 5 A (<2 s) , max. 7.5 A (<0,3 s) per motor | |
| Overload protection | Fuse 4 A, I2t = 122.5 A2s per motor | |
| Velocity signal | US | 0 ... 10 V DC Control via parameter P1:0 |
| Rotation direction signal | UD | PNP digital output low: high impedance high: ≥ 15 V |
| Motor fault | NPN digital input 0 (no error) ≥ 125 µA 1 (error) ≤ 25 µA |
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Fieldbus standard | EN 62026-2:2013 | |
| Input | EN 61131-2:2007 | |
| Emitted interference | EN 61000-6-4:2007 , EN 55011:2016+A1:2017+A11:2020 | |
| AS-Interface | EN 62026-2:2013+A1:2019 | |
| Noise immunity | EN 61000-6-2:2019 , EN 61326-1:2021 , EN 62026-2:2013+A1:2019 |
| Ambient temperature | -25 ... 65 °C (-13 ... 149 °F) | |
| Storage temperature | -30 ... 85 °C (-22 ... 185 °F) | |
| Relative humidity | 85 % non-condensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 5000 m above MSL | |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions, 3 shocks | |
| Vibration resistance | 0.35 mm / 2 g 10 ... 1000 Hz | |
| Pollution degree | 2 |
| Degree of protection | IP67 according to EN 60529 | ||||||||||
| Connection | AS-Interface, AUX: Insulation piercing technology Yellow flat cable/black flat cable Inputs/outputs: M8 round plug connector in accordance with EN 61076-2-104 Inputs: LF004-GS1-A (4-pin, bushing contacts, screw lock, A-coded) Matching connector: LM004-Gx1-A or similar Outputs: NF005-SS1-B (5-pin, bushing contacts, snap lock, B-coded). Matching connector: NM005-Sx1-B or similar | ||||||||||
| Mass | 310 g | ||||||||||
| Dimensions | |||||||||||
| |||||||||||
| Mounting | 2 clips with ∅ 8 mm drill hole | ||||||||||
| Cable length | 1 m | ||||||||||
| Note | The flat cable routing is designed for 100 actuation cycles | ||||||||||