ICA-8IO-4M4-G20-IO-P14 IO-Link Motor Roller Module

G20 MDR module with IO-Link for 8 digital inputs/outputs and 4 connections for MDRs (24 V / 48 V)

주요 혜택 한눈에 보기

  • Configuration and control via IO-Link
  • Connections for 24 V or 48 V DC roller motors
  • Inputs for 2- and 3-wire sensors
  • Electronic PNP outputs
  • Function indicator for motors, inputs and outputs
  • Mounting directly in the support profile

더 보기

Product Compliance: Europe – CE
Product Compliance: USA - cULus
IO-Link interface
참고

Pepperl+Fuchs GmbH 또는 Pepperl+Fuchs AG 명의로 전환 이전에 발행된 인증서, 적합성 선언서 등 모든 제품 관련 서류는 Pepperl+Fuchs SE에도 적용됩니다.

EN
  • EN
  • DE
  • FR

ICA-8IO-4M4-G20-IO-P14 기술 데이터

UL File NumberE223772 "For use in NFPA 79 Applications only"
MTBF90 a
Compatible roller motorsInterroll EC310
Interroll EC5000 24 V AI (20 W / 35 W / 50 W)
Interroll EC5000 48 V AI (20 W / 35 W / 50 W)
Rulmeca BL3
Itoh Denki PM500XK
Itoh Denki PM500XC
PULSEROLLER Senergy-IDC
MTA MRD50 (A interface, 24 V to 40 W)
MTA MRD50 (A interface, 48 V to 44 W)
WWL R-*-H + CE23XX
Conveline RM50
Mambaroll Built-In Drive Roller 50
UniDrive ONE
LED yellow/redIO1 ... IO8: IN, OUT, IO-Link status
M1 ... M4: motor status
Auxiliary voltageUPWR18 ... 56 V DC PELV Max. 10 A
Current limitation of the supply max. 30 A
For UL: Z-type miniature circuit breaker in accordance with UL 1077, max. 20 A, required
Operating voltageUB18 ... 30 V DC, PELV
Current limitation of the supply max. 4 A
No-load supply currentI0≤ 25 mA
Operating currentIBmax. 2.5 A
Interface typeIO-Link
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D
Firmware update
Process data8 byte inputs (STD/EXT)
6 byte outputs (STD)
18 byte outputs (EXT)
Vendor ID1 (0x0001)
Device ID984068 (0x0F0404) (STD) - default
984067 (0x0F0403) (EXT)
Data transfer rateCOM3 (230.4 kbits/s)
Min. cycle time1.2 ms (STD)
2 ms (EXT)
SIO mode supportno
Compatible master port typeClass A
Number/Type8 Inputs for 3-wire sensors (PNP), DC (IO1 ... IO8)
Supplyfrom IO-Link
Current loading capacity200 mA per connection IO1/2 ... IO7/8 , overload and short-circuit protected
Input current≤ 5 mA (limited internally)
Switching pointType 3 according to IEC 61131-2
Number/Type8 electronic outputs, PNP (IO1 … IO8), overload proof and short-circuit proof
Supplyfrom IO-Link
Current200 mA per output
Voltage≥ (Ue - 1.5 V)
Number/Type4 outputs for DC roller motors (MOT1 ... MOT4)
Supplyvia UPWR
Current loading capacity3.5 A (continuous), 5 A (< 2 s), max. 7.5 A (< 0.3 s) per motor
Total current (continuous)
max. 10 A per device (TB ≤ 50 °C)
max. 6 A per device (TB ≤ 60 °C)
Overload protectionFuse 4 A, I2t = 122.5 A2s per motor
Signal levelSpeed: US = 0.3 … 10 V in no-load operation
Ri = 5.6 kΩ, RLOAD ≥ 35 kΩ
Direction of rotation: Digital output PNP
UD low = high resistance
UD high ≥ 12 V
Ri = 5.6 kΩ, RLOAD ≥ 15 kΩ
Fault levelMotor fault: Digital input NPN
0 (no error) ≥ 125 µA
1 (error) ≤ 25 µA
Electromagnetic compatibility
Directive 2014/30/EUEN 61000-6-2:2005-08
EN 61000-6-4:2007-01 EN 61000-6-4/A1:2011-02
Degree of protectionEN 60529:2000
InputEN 61131-2:2007
Communication interfaceIEC 61131-9 / IO-Link V1.1.3
Emitted interferenceEN 61000-6-4:2007
Noise immunityEN 61000-6-2:2005, EN 61326-1:2006
UL approval
O1 ... O8 (Output 1): Load specification DC General Use / DC Pilot Duty
Degree of protection not tested by UL; tested by Pepperl+Fuchs SE
Ambient temperature-25 ... 60 °C (-13 ... 140 °F)
Storage temperature-30 ... 85 °C (-22 ... 185 °F)
Relative humidity85 % non-condensing
Climatic conditionsFor indoor use only
Altitude≤ 5000 m above MSL
Shock and impact resistance30 g, 11 ms in 6 spatial directions, 3 shocks 10 g, 16 ms in 6 spatial directions,
1000 shocks
Vibration resistance0.35 mm / 5 g 5 ... 500 Hz
Pollution degree2
Degree of protectionIP67 according to EN 60529
Connection24 V/48 V power (PWR): Piercing technology, black or gray flat cable
IO-Link: M12 round plug connector in accordance with EN 61076-2-101, LM type (4-pin, connector contacts, screw-locking, A-coded)
Female connector: LF type or similar
Inputs/outputs (IO), motors (MOT): M8 round plug connector in accordance with EN 61076-2-104
IO: LF type (4-pin, bushing contacts, screw-locking, A-coded)
Female connector: LM type or similar
MOT: NF type (5-pin, bushing contacts, snap-locking, B-coded)
Female connector: NM type or similar
Mass390 g
Dimensions
Height27.5 mm
Width131.5 mm
Length54 mm
Mounting2 clips with ∅ 8 mm drill hole
The module must be secured to a solid, continuous surface using the two lugs
Cable length1 m (IO-Link)
1.5 m (IO1/2, IO7/8), 0.8 m (IO3/4, IO5/6)
1.0 m (MOT1, MOT4); 0.4 m (MOT2, MOT3)
max. 10 m
NoteThe flat cable routing is designed for 100 actuation cycles
일반 참고 사항