국가 선택
PXV100Q-F213-SSI-3M Optical Read Head
Read head for incident light positioning system
주요 혜택 한눈에 보기
- Mechanically rugged: no wearing parts, long operating life, maintenance-free
- Internal flash
- Non-contact positioning on Data Matrix code tape
- SSI interface
- High resolution and precise positioning, especially for facilities with curves and switch points as well as inclines and declines.
더 보기









참고
Pepperl+Fuchs GmbH 또는 Pepperl+Fuchs AG 명의로 전환 이전에 발행된 인증서, 적합성 선언서 등 모든 제품 관련 서류는 Pepperl+Fuchs SE에도 적용됩니다.
EN
- EN
- DE
- ES
- FR
PXV100Q-F213-SSI-3M 기술 데이터
| Passage speed | v | ≤ 12.5 m/s | |||||||||
| Maximum track length | max. 100000 m | ||||||||||
| Light type | Integrated LED lightning (red) | ||||||||||
| Evaluation frequency | 40 s-1 | ||||||||||
| Latency | 50 ms | ||||||||||
| Read distance (z) | 100 mm | ||||||||||
| |||||||||||
| Field of view | 120 mm x 80 mm (for z = 100 mm) | ||||||||||
| |||||||||||
| Ambient light limit | 100000 Lux | ||||||||||
| Accuracy of Data Matrix codes | |||||||||||
| |||||||||||
| Camera | |||||
| |||||
| MTTFd | 97 a |
| LED indication | 2 LEDs (communication, status) |
| Operating voltage | UB | 15 ... 30 V DC , PELV |
| No-load supply current | I0 | max. 200 mA |
| Power consumption | P0 | 3 W (at no-load) |
| Interface type | SSI interface | |
| Data output code | programmable, Gray code, binary code | |
| Process data | Position data (x, y) , speed (bi-directional) , status data , warning | |
| Transfer rate | ||
| Query cycle time | ≥ 3 ms | |
| Clock frequency | 100 ... 1000 kHz | |
| Monoflop time | Tm = 10 µs | |
| Pause time | tp | ≥ 20 µs double request possible, if tp ≤ 10 µs |
| Interface | UART 115,200 baud |
| Number | 0 ... 2 , programmable | |
| Input type | 0 level: unswitched or -UB ... +7 V1 level: +13 V ... +UB | |
| Input impedance | ≥ 30 kΩ |
| Number | 0 ... 2 , programmable | |
| Output type | Push/pull , PNP , NPN , programmable | |
| Switching voltage | Operating voltage | |
| Switching current | 100 mA each output |
| Shock resistance | EN 60068-2-27:2009 | |
| Vibration resistance | EN 60068-2-6:2008 | |
| Emitted interference | EN 61000-6-4:2007+A1:2011 | |
| Noise immunity | EN 61000-6-2:2005 | |
| Photobiological safety | exempt group according to EN 62471:2008 |
| CE conformity | CE | |
| UL approval | cULus Listed, Class 2 Power Source, Type 1 enclosure | |
| CCC approval | CCC approval / marking not required for products rated ≤36 V |
| Operating temperature | 0 ... 60 °C (32 ... 140 °F) , -20 ... 60 °C (-4 ... 140 °F) (non-condensing; prevent icing on the lens!) | |
| Storage temperature | -40 ... 85 °C (-40 ... 185 °F) | |
| Relative humidity | 90 % , non-condensing |
| Connection type | Open cable end | |||||||||||||
| Degree of protection | IP54 | |||||||||||||
| Material | ||||||||||||||
| ||||||||||||||
| Cable | ||||||||||||||
| ||||||||||||||
| Mass | approx. 200 g | |||||||||||||
| Dimensions | ||||||||||||||
| ||||||||||||||
| SSI coding | digital | |
| Data content | X-Position (22 Bit), Status (3 Bit) | |
| Orientation | 0 ° / 180 ° | |
| Resolution x-position | 1 mm | |
| Resolution y-position | 1 mm | |
| Speed resolution | 0.1 m/s | |
| X-offset | 0 mm | |
| Behaviour in case of missing x-position data | Substitute value 0 | |
| Behaviour in case of missing y-position data | Substitute value 0 | |
| Behaviour in case of missing speed data | Substitute value 2147483647 | |
| Extrapolation | Linear extrapolation | |
| Marker position | Event marker instead of code tape | |
| Output 2 (OUT2) | PP, Quality Values (Threshold 4) | |
| Output 3 (OUT3) | No function |