VBA-4E-G11-ZAJ-V1 ASi Input Module
G11 module, 4 inputs
주요 혜택 한눈에 보기
- Inputs for 2-, 3-, and 4-wire sensors
- Supply of sensors from AS-Interface
- Function display for bus and inputs
- Communication monitoring
- Degree of protection IP68 / IP69K
- AS-Interface POWER24
더 보기









참고
Pepperl+Fuchs GmbH 또는 Pepperl+Fuchs AG 명의로 전환 이전에 발행된 인증서, 적합성 선언서 등 모든 제품 관련 서류는 Pepperl+Fuchs SE에도 적용됩니다.
EN
- EN
- DE
- FR
- ZH
VBA-4E-G11-ZAJ-V1 기술 데이터
| Node type | A/B node | |||||||||||||
| AS-Interface specification | V3.0 | |||||||||||||
| Required gateway specification | ≥ V2.1 | |||||||||||||
| Profile | S-0.A.2 | |||||||||||||
| ||||||||||||||
| UL File Number | E223772 | |||||||||||||
| LED AS-i/FAULT | Status display; multi-colour LED Green: normal operation Red: communication fault Flashing yellow/red: address 0 Flashing green/red: sensor supply overload | |
| LED IN | switching state (input); 4 LED yellow |
| Rated operating voltage | Ue | 18,0 ... 31.6 V from AS-Interface |
| Rated operating current | Ie | ≤ 40 mA (without sensors) / max. 240 mA |
| Protection class | III | |
| Surge protection | Ue: Over voltage category III, safe isolated power supplies (PELV) |
| Number/Type | 4 inputs for 2- or 3-wire sensors (PNP), DC option 2 inputs for 4-wire sensors (PNP), DC | |||||||
| Supply | from AS-Interface | |||||||
| Voltage | 12 ... 31 V | |||||||
| Current loading capacity | ≤ 200 mA, overload and short-circuit protected | |||||||
| Input current | ≤ 9 mA (limited internally) | |||||||
| Switching point | according to DIN EN 61131-2 (Type 2) | |||||||
| ||||||||
| Signal delay | < 1 ms (input/AS-Interface) | |||||||
| Electromagnetic compatibility | |||||
| |||||
| Degree of protection | EN 60529:2000 | |
| Fieldbus standard | EN 62026-2:2013 | |
| Input | EN 61131-2:2007 | |
| Emitted interference | EN 61000-6-4:2007 | |
| AS-Interface | EN 62026-2:2013 | |
| Noise immunity | EN 61000-6-2:2005, EN 61326-1:2006, EN 62026-2:2013 |
| Ambient temperature | -25 ... 70 °C (-13 ... 158 °F) | |
| Storage temperature | -25 ... 85 °C (-13 ... 185 °F) | |
| Relative humidity | 85 % , non-condensing | |
| Climatic conditions | For indoor use only | |
| Altitude | ≤ 2000 m above MSL | |
| Shock and impact resistance | 30 g, 11 ms in 6 spatial directions 3 shocks 10 g, 16 ms in 6 spatial directions 1000 shocks | |
| Vibration resistance | 0.75 mm 10 ... 57 Hz , 5 g 57 ... 150 Hz, 20 cycles | |
| Pollution degree | 3 |
| Degree of protection | IP68 / IP69K | |||||||
| Connection | AS-Interface: M12 round connector Inputs: M12 round connector | |||||||
| Material | ||||||||
| ||||||||
| Mass | 200 g | |||||||
| Tightening torque, housing screws | 1.8 Nm | |||||||
| Tightening torque, cable gland | 0.4 Nm | |||||||
| Dimensions | ||||||||
| ||||||||
| Mounting | Mounting plate | |||||||