VIM32PP-E7DC8-0RE-IO-1V1401 Vibration Sensor

Vibration sensor with IO-Link and programmable switching output or analog current output

Najważniejsze zalety w skrócie

  • Raw data for vibration acceleration a-Raw by means of BLOB transfer
  • Frequency range up to 12 kHz with sampling rate up to 64 kHz
  • Bearing status parameter according to DIN ISO 13373
  • Vibration velocity in mm/s (rms) acc. to DIN ISO 10816/20816
  • Vibration acceleration in g (rms) acc. to DIN ISO 10816/20816
  • Additional temperature value output
  • IO-Link Interface for process data, parameterization and diagnosis
  • Rugged stainless steel housing

Pokaż więcej

Product Compliance: Europe – CE
Product Compliance: USA - cULus
Product Compliance: United Kingdom – UKCA
IO-Link interface
Uwaga

Wszystkie dokumenty dotyczące produktów, takie jak certyfikaty, deklaracje zgodności itp., które zostały wydane przed przekształceniem pod nazwą Pepperl+Fuchs GmbH lub Pepperl+Fuchs AG, mają również zastosowanie do spółki Pepperl+Fuchs SE.

EN
  • EN
  • DE
  • ES
  • FR

Dane techniczne produktu VIM32PP-E7DC8-0RE-IO-1V1401

TypeVibration sensor
Measuring technologyMEMS capacitive
SeriesPerformance Plus Line
Measured variableVibration velocity
Vibration acceleration
Bearing status parameter
Crest factor
Temperature
Measuring range
Vibration velocityv-rms0 ... 128 mm/s
Vibration accelerationa-rms0 ... 34 g rms
Vibration accelerationa-Peak0 ... 48 g peak value per 1 s
Vibration accelerationa-Raw-48 ... 48 g by means of BLOB transfer
Bearing status parameter1 ... 4
see section characteristic curve
Crest factor0 ... 100
Temperature-40 ... 85 °C (-40 ... 185 °F)
Measurement accuracyVibration velocity: ± 0.1 mm/s (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954 for measuring range greater than 8 mm/s
Vibration acceleration: ± 0.01 g (calibration point: 90% of the measuring range; 159.2 Hz) Complies with the tolerance requirements of DIN ISO 2954
Cross-sensitivity< 5 % of the partial lateral acceleration, which acts exactly 90° to the measuring axis
ResolutionVibration velocity: 0.01 mm/s
Vibration acceleration: 0.01 g
Bearing status parameter: 0.01
Frequency rangeVibration acceleration a-raw: 0 ... 12000 Hz , by means of BLOB transfer
Vibration velocity rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable
Vibration acceleration rms: 10 ... 1000 Hz , acc. to DIN ISO 10816/20816 , programmable
Vibration acceleration a-peak: 10 ... 10000 Hz
Crest factor: 10 ... 10000 Hz
Bearing status parameter: 10 ... 10000 Hz , acc. to DIN ISO 13373-3
Averaging timefor v-rms: 2 s
for a-rms: 2 s
Sampling rateVibration acceleration a-raw: 64 kHz , programmable
Vibration velocity rms: 8 kHz
Vibration acceleration rms: 8 kHz
Vibration acceleration a-peak: 32 kHz
Crest factor: 32 kHz
Bearing status parameter: 32 kHz
MTTFd329 a
Mission Time (TM)20 a
Diagnostic Coverage (DC)0 %
Fusingexternal fuse is required: 1 A , fast acting , 30 V DC
Operating voltageUB18 ... 30 V DC
Current consumptionmax. 320 mA
Power consumptionP0max. 10 W
Time delay before availabilitytv≤ 3.6 s
Surge protectionup to 2 kV
Interface typeIO-Link (via C/Q = Pin 4)
IO-Link revision1.1
Device profileIdentification and Diagnosis - I&D , BLOB transfer
Process dataInput 24 Byte
measurement channels:
-rms value velocity
- peak value acceleration
- rms value acceleration
- temperature
- crest factor
- bearing status parameter
per measurement channel:
- measurement value 2 Byte
- scaling 8 Bit
- switching signals 2 Bit
status data
Vendor ID1 (0x0001)
Device ID5308673 (0x510101)
Transfer rateCOM3 (230.4 kbits/s)
Min. cycle time3.8 ms
SIO mode supportyes
Compatible master port typeClass A
Class B (use 3-pole adapter or 3-wire cable)
BLOB size1.28 MByte , programmable
BLOB segments200 Byte per request and BLOB segment respectively
Output typeC/Q - Pin 4 in SIO mode (switching signal of the measured variable is programmable)
Switching functionNormally open/closed (NO/NC)
Operating current≤ 100 mA
Short-circuit protectionyes
Output typeI/Q - pin 2 (parameterizable as analog current output or switching signal)
- I: analog output for the measured variable, current 4 ... 20 mA
- Q: switching signal of the measured variable is parameterizable, PNP normally open
Switching functionNormally open/closed (NO/NC)
Operating current≤ 120 mA for switching signal
Voltage drop< 2 V
Output current4 ... 20 mA at analog output
Load resistor≤ 500 Ω at analog output
Short-circuit protectionyes
Degree of protectionDIN EN 60529, IP66, IP67
Shock resistanceDIN EN 60068-2-27, 60 g, 6 ms
Vibration resistanceDIN EN 60068-2-6, 16.5 g, 10 ... 12000 Hz
Vibration evaluationDIN ISO 10816/20816 , DIN ISO 13373-3
UL approval
Ordinary LocationE468231 cULus Listed, Class III Power Source and limited energy , if UL marking is marked on the product. For use in NFPA 70 Applications only.
adapters providing field wiring on request
Maximum permissible ambient temperaturemax. 80 °C (max. 176 °F)
Ambient temperature-40 ... 85 °C (-40 ... 185 °F)
Storage temperature-40 ... 85 °C (-40 ... 185 °F)
Connection typeplug
Housing materialStainless steel 1.4305 / AISI 303
Degree of protectionIP66 / IP67 only in connected state
Connector
ThreadingM12
Number of pins4
Massapprox. 100 g
Dimensions
Length72.5 mm
Diameter23.8 mm
Uwagi ogólne