Przejdź do globalnej strony internetowej
Analog output 0 ... 10 V, Scalable measuring range, programmable via key, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterizable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable , 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterizable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable , 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterizable measuring range, Analog current or voltage output, programmable, 2 Push-pull outputs, Switching element function: Analog current or voltage output, programmable , 2 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4)
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 104 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 210 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output, load-dependent voltage or current, Parameterizable measuring range, Measuring range: max. 360° , min. 45°, Operating voltage: 18 ... 30 V DC, Output type: current output or voltage output (load dependend) , 4 ... 20 mA (RL < 400 Ω) , 0 ... 10 V (RL > 3.3 kΩ), UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 120 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterizable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmable
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 120 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 360 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Measuring range 0 ... 360°, Analog output 4 mA ... 20 mA, Adjustable switch points, Output polarity: DC, Measuring range: 360°, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC , Output Switching Current: 100 mA
Analog output, load-dependent voltage or current, 2 configurable switching frames, Parameterizable measuring range, Measuring range: max. 360° , min. 45°, Operating voltage: 18 ... 30 V DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable, Output type: current output or voltage output (load dependend) , 4 ... 20 mA (RL < 400 Ω) , 0 ... 10 V (RL > 3.3 kΩ)
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterizable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmable
Measuring range 0 ... 40 mm, Analog output 0 ... 10 V DC, Switching element function: analog voltage output, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Output type: voltage output 0 ... 10 V DC, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, Connection type: 5-pin, M12 x 1 connector, Degree of protection: IP67 / IP69K
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 510 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 80 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 80 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 4 mA ... 20 mA, Adjustable switch points, Measuring range 0 ... 104 mm, Switching element function: Analog current output with PNP binary NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected, Output type: 1 current output: 4 ... 20 mA
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 120 mm, Parameterizable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection , , overvoltage protected
Parameterization and diagnosis via IO-Link, 2 configurable switching frames, Measuring range 0 ... 14 mm, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Shielded line 2 m, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, CCC approval: CCC approval / marking not required for products rated ≤36 V
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Shielded line 2 m, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Parameterization and diagnosis via IO-Link, Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link, Output type: voltage output 0 ... 10 V, UL approval: cULus Listed, Class 2 Power Source, Type 1 enclosure, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: Cable connector
Measuring range 0 ... 14 mm, 2 programmable switch outputs, Switching element function: PNP Dual NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: PNP (2 Channels), UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, Connection type: 5 x 0.14 mm2 , screened 2 m PUR cable, Degree of protection: IP65
Measuring range 0 ... 14 mm, 2 programmable switch outputs, Switching element function: PNP Dual NO, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: PNP (2 Channels), Connection type: fixed cable with plug, Degree of protection: IP65, Housing: Zinc diecast, nickel-plated , cover , PBT, Threading: M12 x 1
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, Connection type: fixed cable with plug, Degree of protection: IP65, Housing: Zinc diecast, nickel-plated , cover , PBT, Threading: M12 x 1
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, Connection type: 1 m, PUR cable, Housing: Zinc diecast, nickel-plated , cover , PBT
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 push-pull (4 in 1) output, short-circuit protected, reverse polarity protected, overvoltage protected
IO-Link interface for service and process data, Measuring range 0 ... 15 mm, Switching element function: Push-pull (4 in 1) output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 1 Push-pull (4 in 1) output , short-circuit protected , reverse polarity protected , overvoltage protected , programmable
3 configurable switching frames, Measuring range: max. 360° , min. 5°, Operating voltage: 18 ... 30 V DC, Output type: 3 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC , Output Switching Current: 3 x 100 mA, CCC approval: CCC approval / marking not required for products rated ≤36 V
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 40 mm, Parameterizable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection , , overvoltage protected
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterizable measuring range, 3 Push-pull outputs, Switch points programmable via IO-Link, Switching element function: 3 switch outputs, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC, Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: 3 push-pull outputs (can be parameterized), short-circuit-proof, reverse polarity protection , , overvoltage protected
Parameterization and diagnosis via IO-Link, Measuring range 0 ... 80 mm, Parameterizable measuring range, Analog current or voltage output, programmable, Switching element function: Analog current or voltage output, programmable, Output polarity: DC, Operating voltage: 12 ... 30 V DC , (13 ... 30 V when analog voltage output is parameterized), Type of voltage: DC, Interface type: IO-Link (via C/Q = Pin 4), Output type: current output 4-20 mA voltage output 0 - 5 V DC 0 ... 10 V DC , programmable
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 810 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Operating voltage: 18 ... 30 V DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: Resistive , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC
Analog position indicator with end position monitoring, 2 configurable switching frames, Preset range of angle measurement 0 ... 90°, Extended analog signal range, Measuring range: max. 180° , min. 90°, Operating voltage: 18 ... 30 V DC, Output type: 2 switch outputs PNP, NO , reverse polarity protected , short-circuit protected , programmable, Output type: current output , 3.8 ... 20.5 mA (RL < 400 Ω)
Analog output 0 V ... 10 V/4 mA ... 20 mA, Measuring range 0 ... 960 mm, Switching element function: analog, current or voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 current output: 4 ... 20 mA , 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Load Type: General Purpose , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, CCC approval: CCC approval / marking not required for products rated ≤36 V
Parameterization and diagnosis via IO-Link, 3 configurable switching frames, Measuring range 0 ... 14 mm, Shielded line 2 m, Output polarity: DC, Type of voltage: DC, Interface type: IO-Link, Output type: 2 Push-pull (4 in 1) outputs , 1 switch output PNP , short-circuit protected , reverse polarity protected , overvoltage protected , programmable, CCC approval: CCC approval / marking not required for products rated ≤36 V, Connection type: 2 m PUR cable , screened
Analog output 0 ... 10 V, Measuring range 0 ... 14 mm, Scalable measuring range programmable via cable, Switching element function: Analog voltage output, Output polarity: DC, Type of voltage: DC, Output type: 1 voltage output: 0 ... 10 V, UL approval: cULus Listed , Circuitry: Class 2 Power Source , Enclosure Type Rating: Type 1 , Supply/Switching Voltage: 30 V DC, Connection type: fixed cable with plug, Housing: Zinc diecast, nickel-plated , cover , PBT
46 / 46
Zapoznaj się z najnowszymi wiadomościami i zastosowaniami dotyczącymi wybranych przez Ciebie produktów.